An intermittent error may occur following an installation or upgrade of Flyway Desktop (FWD), where the FWD GUI fails to open.
Due to third-party component Electron, this error occurs when its files become invalid and an error message is thrown:
Invalid file descriptor to ICU data received
.
There are number of causes, which can include:
- Security permissions
- File corruption of the downloaded installer
- Files not being released for update
The most reliable way of resolving this problem is to uninstall the current FWD installation and check that the installation folder has been completely removed, which by default is in this path: C:\Program Files\Red Gate\Flyway Desktop, then reinstall Flyway Desktop.
If the problem persists after reinstalling, please submit a support request.
1
-1
Was this article helpful?
0 out of 1 found this helpful